A manual ventilator used in patients with respiratory problems. It is based on the forced supply of air to the lungs with the help of a mask by compressing the bag, which fills itself. Tidal volume depends on the degree of compression of the bag, and the frequency of air supply and minute ventilation of the lungs depend on the intensity of the doctor's actions.
Specifications:
Complete set: anesthesia mask, breathing bag, oxygen bag, oxygen tube, air ducts (Berman type);
Reusable AMBU bags are made of: anesthesia mask (silicone), breathing bag (silicone), oxygen bag (silicone), oxygen tube (polyvinyl chloride), air ducts (polypropylene) case (polypropylene);
Reusable (autoclavable);
Operating temperature range: -18 +50 С;
Storage temperature range: -40 +60 С;
Gas inlet connector.
Description Dimensions
Patient Port Inner diameter: 15mm;
Outside diameter 22mm
Bag Connector Inner diameter: 25mm;
Oxygen tank Inner diameter: 25mm;
oxygen valve Outer Diameter: 6mm;
Type | Mask size | Tank volume | Dead space | Pressure with open pressure relief valve | Breathing bag volume | Oxygen bag volume | The volume of the outgoing air mixture | Maximum compressions per minute | oxygen tube |
Adult | 5 | 1800ml | 168ml | 60±10cmH20 | 1500ml | 2500ml | 800ml1350ml | 45VRM | 2.1 m |
Children's | 3 | 750ml | 113ml | 40±5cmH20 | 550ml | 2500ml | 350ml | 105BPM | 2.1 m |
For babies | 1 | 500ml | 46ml | 40±5cmH20 | 280ml | 600ml | 100ml | 98BPM | 2.1 m |
Instructions for use:
Clear the patient's airway of foreign objects before using the counterlung;
Tilt the patient's head back and pull the chin up to open the airway;
Perform mechanical ventilation of the patient, alternately squeezing and releasing the bag with the required frequency;
Make sure the patient is ventilated (alternately raising and lowering the chest, changing the color of the lips and face);
Coordinate ventilation efforts with spontaneous breathing to allow the patient to passively exhale;
If foreign objects such as blood or vomit appear in the mask, remove the device from the patient and clear the airway;
Clear the device of the remnants of foreign matter by rapidly squeezing the bag. Shake the device to remove substances in the mask and valve;
Dispose of device and mask after use.
A manual ventilator used in patients with respiratory problems. It is based on the forced supply of air to the lungs with the help of a mask by compressing the bag, which fills itself. Tidal volume depends on the degree of compression of the bag, and the frequency of air supply and minute ventilation of the lungs depend on the intensity of the doctor's actions.
Specifications:
Complete set: anesthesia mask, breathing bag, oxygen bag, oxygen tube, air ducts (Berman type);
Reusable AMBU bags are made of: anesthesia mask (silicone), breathing bag (silicone), oxygen bag (silicone), oxygen tube (polyvinyl chloride), air ducts (polypropylene) case (polypropylene);
Reusable (autoclavable);
Operating temperature range: -18 +50 С;
Storage temperature range: -40 +60 С;
Gas inlet connector.
Description Dimensions
Patient Port Inner diameter: 15mm;
Outside diameter 22mm
Bag Connector Inner diameter: 25mm;
Oxygen tank Inner diameter: 25mm;
oxygen valve Outer Diameter: 6mm;
Type | Mask size | Tank volume | Dead space | Pressure with open pressure relief valve | Breathing bag volume | Oxygen bag volume | The volume of the outgoing air mixture | Maximum compressions per minute | oxygen tube |
Adult | 5 | 1800ml | 168ml | 60±10cmH20 | 1500ml | 2500ml | 800ml1350ml | 45VRM | 2.1 m |
Children's | 3 | 750ml | 113ml | 40±5cmH20 | 550ml | 2500ml | 350ml | 105BPM | 2.1 m |
For babies | 1 | 500ml | 46ml | 40±5cmH20 | 280ml | 600ml | 100ml | 98BPM | 2.1 m |
Instructions for use:
Clear the patient's airway of foreign objects before using the counterlung;
Tilt the patient's head back and pull the chin up to open the airway;
Perform mechanical ventilation of the patient, alternately squeezing and releasing the bag with the required frequency;
Make sure the patient is ventilated (alternately raising and lowering the chest, changing the color of the lips and face);
Coordinate ventilation efforts with spontaneous breathing to allow the patient to passively exhale;
If foreign objects such as blood or vomit appear in the mask, remove the device from the patient and clear the airway;
Clear the device of the remnants of foreign matter by rapidly squeezing the bag. Shake the device to remove substances in the mask and valve;
Dispose of device and mask after use.