Callback?
Compare List 0 View Cart 0

Disposable breathing circuit "MEDICARE" for newborns, with heating of the inhalation line, with a camera

Product Code: 4649
Product Code: 4649
Not available
140.0 uah
Savings on payment by Visa, Mastercard
Delivery change city
estimate -

The respiratory circuit ensures the maintenance of adequate gas exchange while replacing the function of external respiration. It is used to supply a respiratory mixture of gases from the ventilator to the patient during short-term and prolonged mechanical ventilation in various modes, inhalation anesthesia. For newborns.

Specifications:

Equipment:

  1. 1 blue heated corrugated tube: length 110 cm and diameter 10 mm, made of ethylene vinyl acetate + polyethylene;
  2. 1 blue corrugated tube: length 60 cm and diameter 12 mm, made of ethylene vinyl acetate + polyethylene;
  3. 1 blue corrugated tube: length 30 cm and diameter 12 mm, made of ethylene vinyl acetate + polyethylene;
  4. 1 white corrugated tube: length 80 cm and diameter 12 mm, made of ethylene vinyl acetate + polyethylene;
  5. 1 white corrugated tube: 60 cm long and 12 mm in diameter, made of ethylene vinyl acetate + polyethylene;
  6. 1 moisture collector , made of polypropylene;
  7. 1 T-type connector with temperature port, made of polyethylene;
  8. 4 straight connectors, diameter 12mm (M) / 22mm (F), made of polypropylene;
  9. 3 straight connectors, diameter 12mm (M) / 15mm (F), made of polypropylene;
  10. 1 T-type connector with temperature port, made of polyethylene;
  11. 1 L-type connector with port, made of polycarbonate;
  12. 1 Y-type connector with pressure port, made of polypropylene;
  13. 1 pressure line made of PVC;
  14. 1 neonatal humidifier chamber;
  • non-sterile;
  • For single use;
  • Individual packing.

 

Size:

  • For newborns.
 
Instructions for use:
  1. Open the package.
  2. Properly attach the product to the ventilator.
  3. After installation, check for gas leakage.
  4. The product can only be used if there is no gas leakage.
  5. After use, dispose of in accordance with established regulations.

Technical data, photographs, colors of products are presented on the site for reference and may be changed by the manufacturer without prior notice.

Description

The respiratory circuit ensures the maintenance of adequate gas exchange while replacing the function of external respiration. It is used to supply a respiratory mixture of gases from the ventilator to the patient during short-term and prolonged mechanical ventilation in various modes, inhalation anesthesia. For newborns.

Specifications:

Equipment:

  1. 1 blue heated corrugated tube: length 110 cm and diameter 10 mm, made of ethylene vinyl acetate + polyethylene;
  2. 1 blue corrugated tube: length 60 cm and diameter 12 mm, made of ethylene vinyl acetate + polyethylene;
  3. 1 blue corrugated tube: length 30 cm and diameter 12 mm, made of ethylene vinyl acetate + polyethylene;
  4. 1 white corrugated tube: length 80 cm and diameter 12 mm, made of ethylene vinyl acetate + polyethylene;
  5. 1 white corrugated tube: 60 cm long and 12 mm in diameter, made of ethylene vinyl acetate + polyethylene;
  6. 1 moisture collector , made of polypropylene;
  7. 1 T-type connector with temperature port, made of polyethylene;
  8. 4 straight connectors, diameter 12mm (M) / 22mm (F), made of polypropylene;
  9. 3 straight connectors, diameter 12mm (M) / 15mm (F), made of polypropylene;
  10. 1 T-type connector with temperature port, made of polyethylene;
  11. 1 L-type connector with port, made of polycarbonate;
  12. 1 Y-type connector with pressure port, made of polypropylene;
  13. 1 pressure line made of PVC;
  14. 1 neonatal humidifier chamber;
  • non-sterile;
  • For single use;
  • Individual packing.

 

Size:

  • For newborns.
 
Instructions for use:
  1. Open the package.
  2. Properly attach the product to the ventilator.
  3. After installation, check for gas leakage.
  4. The product can only be used if there is no gas leakage.
  5. After use, dispose of in accordance with established regulations.

Technical data, photographs, colors of products are presented on the site for reference and may be changed by the manufacturer without prior notice.

Advantages
Specialist consultation Specialist consultation
Sending without prepayment Sending without prepayment
Free delivery to home or work Free delivery to home or work
Settlement: Cash, Non-cash (with or without VAT), cash on delivery Settlement: Cash, Non-cash (with or without VAT), cash on delivery
Wholesale discounts Wholesale discounts
Do you need expert advice?
Leave your contacts and we will contact you shortly
Im\'i must be between 2 and 32 characters
Please fill in the correct phone number
Specialist consultation Specialist consultation
Sending without prepayment Sending without prepayment
Free delivery to home or work Free delivery to home or work
Settlement: Cash, Non-cash (with or without VAT), cash on delivery Settlement: Cash, Non-cash (with or without VAT), cash on delivery
Wholesale discounts Wholesale discounts
Your shopping cart is empty!
But it can be fixed
Go shopping