Forlumbar punctureand the introduction of medical solutionsinto the subarchaic spacefor medical purposes or duringspinal anesthesia.
Specifications:
Complete set: needle, stylet and protective tube;
Needle gauge: 26G (0.45mm);
Needle length: 3 ½ (88mm);
Tip type: Pencil or Quincke;
Needle type with introducer/guide and without guide;
Sterile, non-pyrogenic, non-toxic;
For single use;
Individual packing;
The term of use is 5 years from the date of manufacture indicated on the package.
Dimensions:
Needle diameter (caliber): 26G (0.45mm);
Needle length: 3 ½ (88mm).
Instructions for use:
Remove the product from the packaging, check its integrity.
Carry out proper treatment of the puncture site.
Gently insert the spinal needle into the subarachnoid space. The appearance of cerebrospinal fluid confirms that the spinal needle has entered the subarachnoid space.
Plug in the syringe.
The introduction of the anesthetic solution should be carried out at the same rate. At the same time, it is necessary to constantly monitor the patient's condition in accordance with the requirements for spinal anesthesia.
After the injection is completed, the spinal needle must be removed.
At the end of the manipulation, dispose of the product in accordance with the established norms.
Description
Forlumbar punctureand the introduction of medical solutionsinto the subarchaic spacefor medical purposes or duringspinal anesthesia.
Specifications:
Complete set: needle, stylet and protective tube;
Needle gauge: 26G (0.45mm);
Needle length: 3 ½ (88mm);
Tip type: Pencil or Quincke;
Needle type with introducer/guide and without guide;
Sterile, non-pyrogenic, non-toxic;
For single use;
Individual packing;
The term of use is 5 years from the date of manufacture indicated on the package.
Dimensions:
Needle diameter (caliber): 26G (0.45mm);
Needle length: 3 ½ (88mm).
Instructions for use:
Remove the product from the packaging, check its integrity.
Carry out proper treatment of the puncture site.
Gently insert the spinal needle into the subarachnoid space. The appearance of cerebrospinal fluid confirms that the spinal needle has entered the subarachnoid space.
Plug in the syringe.
The introduction of the anesthetic solution should be carried out at the same rate. At the same time, it is necessary to constantly monitor the patient's condition in accordance with the requirements for spinal anesthesia.
After the injection is completed, the spinal needle must be removed.
At the end of the manipulation, dispose of the product in accordance with the established norms.