Callback?
Compare List 0 View Cart 0

Tube endobronchial "MEDICARE" (left-sided) size 35

Product Code: 4459
Product Code: 4459
Not available
2,366.0 uah
Savings on payment by Visa, Mastercard
Delivery change city
estimate -

Tubes with low pressure cuffs for separate lung ventilation; for separate ventilation of the lungs in thoracic surgery, as well as in resuscitation with asymmetric lung damage.

Specifications:

  1. The tube is made of polyvinyl chloride;
  2. In assortment - right-hand and left-hand;
  3. double lumen;
  4. The rounded end of the tube prevents tissue injury during insertion;
  5. Two low pressure cuffs (tracheal and bronchial) ;
  6. The tube set consists of: tube, stylet, connector for simultaneous ventilation of both lungs, 2 suction catheters;
  7. Bronchial cuff blue, tracheal transparent;
  8. Pilot balloons of the tracheal and bronchial cuffs are marked;
  9. The tracheal and bronchial passages are marked;
  10. The tracheal and bronchial passages have connectors with "ears";
  11. Sizes: 28, 32, 35, 37, 39;
  12. A radiopaque strip along the entire length of the tube after 1 cm allows you to accurately determine the location of the tube;
  13. In the right-sided tubes, the bronchial cuff has holes for the mouth of the upper lobe bronchus;
  14. Intubation depth scale;
  15. Stiletto guide to stiffen the tube during installation;
  16. Sterile, non-pyrogenic, non-toxic;
  17. For single use;
  18. Individual packing;
  19. Shelf life 5 years from the date of manufacture indicated on the package.

Dimensions:

Size Inner diameter External diameter Length, mm
28 4.5 7.0 330
32 5.3 7.7 330
35 7.0 9.5 330
37 7.5 10.0 330
39 7.5 10.0 330
41 8.0 10.5 330

Instructions for use:

  1. Remove the tube from the individual packaging;
  2. Before inserting the endobronchial tube, ensure that the cuffs are not inflated;
  3. When the patient is under anesthesia, a tube of the selected size must be inserted into the trachea so that the tracheal cuff is below the vocal cords;
  4. Inflate cuffs;
  5. If necessary, check tube placement by auscultation or bronchoscopy. After that, the tube is connected to the ventilator;
  6. Before removing the tubing through the pilot balloon, purge the air from the cuffs with a syringe;
  7. Remove tube;
  8. After the end of the manipulation, dispose of the product in accordance with the established norms.
Description

Tubes with low pressure cuffs for separate lung ventilation; for separate ventilation of the lungs in thoracic surgery, as well as in resuscitation with asymmetric lung damage.

Specifications:

  1. The tube is made of polyvinyl chloride;
  2. In assortment - right-hand and left-hand;
  3. double lumen;
  4. The rounded end of the tube prevents tissue injury during insertion;
  5. Two low pressure cuffs (tracheal and bronchial) ;
  6. The tube set consists of: tube, stylet, connector for simultaneous ventilation of both lungs, 2 suction catheters;
  7. Bronchial cuff blue, tracheal transparent;
  8. Pilot balloons of the tracheal and bronchial cuffs are marked;
  9. The tracheal and bronchial passages are marked;
  10. The tracheal and bronchial passages have connectors with "ears";
  11. Sizes: 28, 32, 35, 37, 39;
  12. A radiopaque strip along the entire length of the tube after 1 cm allows you to accurately determine the location of the tube;
  13. In the right-sided tubes, the bronchial cuff has holes for the mouth of the upper lobe bronchus;
  14. Intubation depth scale;
  15. Stiletto guide to stiffen the tube during installation;
  16. Sterile, non-pyrogenic, non-toxic;
  17. For single use;
  18. Individual packing;
  19. Shelf life 5 years from the date of manufacture indicated on the package.

Dimensions:

Size Inner diameter External diameter Length, mm
28 4.5 7.0 330
32 5.3 7.7 330
35 7.0 9.5 330
37 7.5 10.0 330
39 7.5 10.0 330
41 8.0 10.5 330

Instructions for use:

  1. Remove the tube from the individual packaging;
  2. Before inserting the endobronchial tube, ensure that the cuffs are not inflated;
  3. When the patient is under anesthesia, a tube of the selected size must be inserted into the trachea so that the tracheal cuff is below the vocal cords;
  4. Inflate cuffs;
  5. If necessary, check tube placement by auscultation or bronchoscopy. After that, the tube is connected to the ventilator;
  6. Before removing the tubing through the pilot balloon, purge the air from the cuffs with a syringe;
  7. Remove tube;
  8. After the end of the manipulation, dispose of the product in accordance with the established norms.
Advantages
Settlement: Cash, Non-cash (with or without VAT), cash on delivery Settlement: Cash, Non-cash (with or without VAT), cash on delivery
Do you need expert advice?
Leave your contacts and we will contact you shortly
Im\'i must be between 2 and 32 characters
Please fill in the correct phone number
Settlement: Cash, Non-cash (with or without VAT), cash on delivery Settlement: Cash, Non-cash (with or without VAT), cash on delivery
Your shopping cart is empty!
But it can be fixed
Go shopping