Needle for spinal anesthesia. Quincke type 25G 0.5mm * 88mm Medicare (orange)

Product Code: 66250
Product Code: 66250
Not available
29.8 uah
Savings on payment by Visa, Mastercard
Delivery change city
estimate -
Manufacturer: DOPOMOGA-1 LLC
A country: China
Brand: MEDICARE
Product type needles
Purpose for spinal anesthesia
Needle outer diameter 0.5 mm
Needle length 88 mm

Spinal anesthesia needle (Quincke type) size 25G (0.5mm x 88mm) Medicare is designed for puncture and administration of medical solutions during treatment or anesthesia in the patient's subarchaid space.

Advantages

The product is made of sufficiently thin high-quality surgical steel with a smooth surface, which allows for easy and correct atraumatic punctures.

Precise alignment of the instrument and mandrel prevents the side effects of the biopsy. And the colorless base of the needle with a magnifying glass effect is designed to clearly visualize the cerebrospinal fluid.

The medical instrument pavilion has a comfortable grip for the procedure, as well as a different color palette depending on the diameter of the product.

Quincke-type spinal needles do not contain silicone, which is an indicator that the patient will not experience allergic reactions. They also differ in the absence of side effects.

How to use

The Quincke type spinal needle is intended for single use and is available in individual gnotobiological blister packs with instructions for proper use. The shelf life is five years.

The kit also contains a wing plate that can be removed. It is designed for easy fastening and better feeling of the product by the doctor's fingers during the procedure. The introducer is designed for less painful insertion of the spinal instrument and avoiding contact with the patient's skin.

Before spinal anesthesia, intravenous anesthesia should be performed. The introduction of anesthesia can be performed both in a sitting position and laying the patient on his side.

First, the skin should be disinfected and a gnotobiological surgical napkin should be applied to it. Then you need to anesthetize the skin with a thin needle and syringe from the kit.

A guide medical instrument is inserted into the area where anesthesia was performed. After fixing it, a needle for subarachnoid anesthesia is inserted.

In the event that you have reached the ligamentum flavum (you will feel increased resistance), you should remove the mandrin without moving the needle in the tissues and move it to a depth of 5 mm.

Then attach the syringe and administer the local analgesic depending on the required dose. After that, remove the subarachnoid needle together with the guide instrument.

Description
Manufacturer: DOPOMOGA-1 LLC
A country: China
Brand: MEDICARE
Product type needles
Purpose for spinal anesthesia
Needle outer diameter 0.5 mm
Needle length 88 mm

Spinal anesthesia needle (Quincke type) size 25G (0.5mm x 88mm) Medicare is designed for puncture and administration of medical solutions during treatment or anesthesia in the patient's subarchaid space.

Advantages

The product is made of sufficiently thin high-quality surgical steel with a smooth surface, which allows for easy and correct atraumatic punctures.

Precise alignment of the instrument and mandrel prevents the side effects of the biopsy. And the colorless base of the needle with a magnifying glass effect is designed to clearly visualize the cerebrospinal fluid.

The medical instrument pavilion has a comfortable grip for the procedure, as well as a different color palette depending on the diameter of the product.

Quincke-type spinal needles do not contain silicone, which is an indicator that the patient will not experience allergic reactions. They also differ in the absence of side effects.

How to use

The Quincke type spinal needle is intended for single use and is available in individual gnotobiological blister packs with instructions for proper use. The shelf life is five years.

The kit also contains a wing plate that can be removed. It is designed for easy fastening and better feeling of the product by the doctor's fingers during the procedure. The introducer is designed for less painful insertion of the spinal instrument and avoiding contact with the patient's skin.

Before spinal anesthesia, intravenous anesthesia should be performed. The introduction of anesthesia can be performed both in a sitting position and laying the patient on his side.

First, the skin should be disinfected and a gnotobiological surgical napkin should be applied to it. Then you need to anesthetize the skin with a thin needle and syringe from the kit.

A guide medical instrument is inserted into the area where anesthesia was performed. After fixing it, a needle for subarachnoid anesthesia is inserted.

In the event that you have reached the ligamentum flavum (you will feel increased resistance), you should remove the mandrin without moving the needle in the tissues and move it to a depth of 5 mm.

Then attach the syringe and administer the local analgesic depending on the required dose. After that, remove the subarachnoid needle together with the guide instrument.